The Murphy Push/Pull DC Solenoids provide single unit versatility for engine applications, such as shutdown.
One solenoid offers pull/push operation. The RP Series has no internal switches, reduces coil burnout and reduces adjustments while boosting reliability. The solenoid offers high force in its small size. It can be used with most engines’ start systems. A choice of two models and two voltages is available. All models come complete with return spring and rubber seal boot.
Model No: | DC Solenoids Description |
RP2307B | 12VDC, 1 in. (25 mm) stroke, 10 lbf (44 N) pull, 25 lbf (111 N) hold |
RP2308B | 24VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 27 lbf (120 N) hold |
RP2309B | 12VDC, 1-1/2 in. (38 mm) stroke, 13 lbf (58 N) pull, 32 lbf (151 N) hold |
RP2310B | 24VDC, 1-1/2 in. (38 mm) stroke, 17 lbf (75 N) pull, 35 lbf (155 N) hold |
Additional product documentation can be found on our product support website or by clicking the Help Center button above.
Part Number | Model/Description | Notes |
---|---|---|
40700092 | RP2307B — 12VDC, 1 in. (25 mm) stroke, 10 lbf (44 N) pull, 25 lbf (111 N) hold | DC Solenoids |
40700093 | RP2308B — 24VDC, 1 in. (25 mm) stroke, 11 lbf (49 N) pull, 27 lbf (120 N) hold | DC Solenoids |
40700094 | RP2309B — 12VDC, 1-1/2 in. (38 mm) stroke, 13 lbf (58 N) pull, 32 lbf (151 N) hold | DC Solenoids |
40700095 | RP2310B — 24VDC, 1-1/2 in. (38 mm) stroke, 17 lbf (75 N) pull, 35 lbf (155 N) hold | DC Solenoids |
40700067 | SD85 Solenoid Drive Time Delay | Discontinued |
65010108 | Clevis yoke assembly | |
65010110 | Clevis yoke chain assembly | |
40050315 | Threaded rod (1-1/2 in.) | |
00002457 | RPS in-line ball joint | |
00002458 | RPS 90° ball joint |
Models RP2307B and RP2308B give a full 1 in. (25 mm) stroke at 11 pounds (49 N) and hold up to 27 pounds (120 N) at full voltage, continuous duty. They will operate at any stroke less than maximum; see the specifications tab.
Models RP2309B and RP2310B can pull 17 pounds (75 N) with a 1-1/2 in. (38 mm) stroke. They hold up to 35 pounds (155 N) at full voltage, continuous duty. See specifications for holding force at any stroke less than maximum.
The SD85 is used when the solenoid is duty cycled for short time periods such as two-position throttle operation. It also provides enhanced operational control for normal on-off applications. Using the SD85 ensures the energize coil is only powered for one to two seconds with each operation. If the plunger does not seat in that time, it is highly unlikely it will seat. The SD85 activates both coils of the solenoid for a short time then de-energizes the Energize coil. The Hold-in coil is energized as long as the signal to the SD85 is active. This ensures long life of the RP solenoid.
Input voltage: 8 to 30 VDC. See specifications for current ratings.