Float Actuated Oil Level Swichgage instruments are a combination oil level sight gage and adjustable, low and/or high limit switch.
The limit switches are normally open during operation — yet closed if the level drops (or rises) to where the float contacts the limit screw. The contact completes a circuit to ground a magneto or trip a Murphy magnetic switch. The magnetic switch can be used to activate alarms and/or shut down. Models are also available without limit switches. The level instruments can be used on a variety of crankcases, pump gearcases or oil reservoirs — primarily on small engines and pumps. Installation is simple, and these instruments save on reduced downtime and repair costs.
L100 and L100W
L100:
L100W:
L120
L127
Additional product documentation can be found on our product support website or by clicking the Help Center button above.
Part Number | Model | Description |
---|---|---|
15700125 | L100 | Used with Small Engines and Pumps with Non-vented Crankcase |
15700128 | L100W | Used with Small Engines and Pumps with Vented Crankcase |
15700131 | L120 | Used with Machined Surface on Crankcase, such as Witte, National-Oilwell/ Garland |
15700133 | L127 | Used with Machined Surface on Crankcase, specifically, Fairbanks-Morse ZC Series and Bell Engines |